How to Update Digital Cameras Use Olympus Workspace for updating the firmware of Olympus digital cameras. 'Digital Camera Updater' and 'OLYMPUS Master' had been provided previously for the update, but the latest software Olympus Workspace is recommended. Download the OLYMPUS Digital Camera Updater installer to your computer. Exit all other software applications. Double-click the installer to begin installation. Follow the instructions on the installer to complete the installation. By clicking the Download Now button, you acknowledge that you have read and agree to the Olympus Software License.

Olympus

Updated Monday, April 29, 2015.

Driver
  • Today we have to inform you about an issue which can occur when connecting an USB camera like Olympus SC30 / SC50 / SC100 and LC10 / LC20 to all computers equipped with Intel® Series-8 or Intel® Series-9 chipsets.
    Detailed Description
    Phenomena observed, when running OSIS USB cameras using respective computers include:
    • Camera is not recognized
    • Camera initialization fails
    • No live image observed
    • Live image is corrupted
    • Live image stream stops
    The root cause of this failure is a hardware flaw in the Intel® 8 and Intel® 9 chipset itself. A description of the root cause is given by Intel® under: http://www.intel.com/content/dam/www/public/us/en/documents/specification-updates/8-series-chipset-pch-spec-update.pdf
    While the description of the bug in Intel®’s documentation is rather complete (please refer to section ‘Errata’ starting at page 10), the bad news is, that Intel® has set all respective bugs to ‘No Plan to Fix’ which means the problems will persist for all Intel® 8 and Intel® 9 chipset based computers.
    Articles concerned
    Name Version affected
    LC10 All lots
    LC20 All lots
    SC30 All lots
    SC50 All lots
    SC100 All lots
    Support
    Identifying your computer’s chipset revision.
    The respective information regarding the chipset of your computer is accessible using the ‘Device manager’ of your Windows® operating system. To open the device manager:
    ü press the ‘Start’ button
    ü select and press ‘Control Panel’
    ü select and press ‘System’
    ü select and press ‘Device manager’
    The device manager visualizes your computer’s devices using a tree view window. Scroll through this window until you find the entry ‘Universal Serial Bus controllers’. Expand this entry to receive a detailed view of your USB devices.
    Next watch out for an entry starting with ‘ Intel® 8 Series ‘ or ‘ Intel® 9 Series ‘. If your computer does not have a respective entry containing the substring ‘ Intel® 8 Series ‘ or ‘ Intel® 9 Series ‘ your computer is not based on the affected chipset and you may skip the rest of this guide.
    TO FIX THE PROBLEMS DESCRIBED ABOVE YOU HAVE THE FOLLOWING OPTIONS:
    Fixing the problem for all USB 2 and USB 3.0 cameras ( LC10/LC20/
    SC30/SC100 and SC50) by using a separate USB interface card
    Please install the USB3.0 add on controller that is supplied with your OSIS USB camera. Make sure to connect the external power connector of the controller to the PC power supply (necessary cables are included). Install the latest original device drivers (not needed for Windows 8 and higher).
    In case your camera was shipped without an add-on USB controller card, we recommend to use this controller board:
    Delock PCI Express card 89243 2 x USB 3.0
    Note:
    There is a large variety of USB add-on controller cards available from different vendors supporting a wide range of different chipsets and drivers. Some of them may work, others may not. OSIS strongly suggests to only use the model recommended above.
    The manufacturer of the card is not able to guaranty, that all USB add-on controllers do have the latest firmware flashed. In case of acquisition problems it is therefore strongly recommended to check the firmware version of the card to carry version 2024. To update the respective firmware, please download the latest firmware version from:
    ftp://ftp.olympus-sis.com/pub/download/Support/DeLock_USB_Firmware_2024.zip
    And proceed with the installation steps as given below:
    • Extract the file after downloading it. It contains a file “K20XXFWUP1.EXE” and a TXT file containing the Release information
    • Disconnect all USB devices connected from all USB3.0 ports.
    • Execute 'K20XXFWUP1.EXE', read all messages carefully until you can proceed to Update the firmware
    • Restart your computer
    • Check with the device manager that the correct firmware was flashed. Expand “USB-Controller” and open RENESAS Electronics USB 3.0 Host Controller. Open the tab “Advanced”. If 'Firmware Version' is 2024 you succeed in updating the card.
    Fixing the problem for USB2 cameras (LC10/LC20/SC30/SC100 only) by switching off onboard USB 3.0
    Note:
    Switching off USB 3.0 will force all connected USB 3.0 devices to use USB 2.0 only. This will probably slow down these devices.
    Access the BIOS of your computer and try to find a respective entry which allows to configure your computer’s onboard USB support. Switch USB to support USB 2.0 only. This will force your onboard USB controller to support USB 2.0 devices only.
    (Some BIOS versions name this option ”xHCI functionality” which has to be DISABLED. Alternatively, it could also be named “USB Debbuging”. In that case, this option has to be ENABLED. Please refer also to your mainboard reference manual for additional information)
    Save the new BIOS settings and reboot your computer.
    TSI_1-2015_USB_camera_Intel_8-9_rev_FAQ.pdf
  • Please have a look into the attached document to get a FAQ about the netHASP
    netHASP_FAQ_DEU.pdf
    netHASP_FAQ_ENG.pdf
  • As a member of the Windows user group “Users“ I do not have enough privileges to run the Image Analysis Software without any problem.
    As a standard “User” you normally do not have the privilege to save a file into the directory “C:program files”.
    Please ask your administrator to change your account to be a member of the group “Power Users” or let him change your privileges for the Image Analysis Software directory only. You need full access to the program folder of your Image Analysis Software.
  • Computer crashes with 'KMode exception not handled'
    This is a problem of the Logitech Mouse driver. If you remove the USB mouse and start windows, there should be no problem. You can plug in the mouse at the log-in screen and start windows without any problems. To avoid these problems, there are two possibilities:
    • Connect a PS/2 mouse instead of an USB mouse
    • Remove the Logitech driver and use the standard Microsoft driver
  • Loading images stored as JPEG-without-compression is not possible with third party applications
    There are only a handful of programs available on the market which can handle this special JPEG-without-compression format. To save such lossless images please use the uncompressed TIF format this can be read by many applications.
  • Loading 16-bit images in other applications is not possible if the images were stored with the image analysis software
    Many applications, like Adobe Photoshop or Microsoft Word, only support a small variety of possible TIF standards. They don’t support the 16-bit TIF image format. You have to switch the color depth of such images to 8-bit or 24-bit using the image analysis software.
  • Latest documentation of the Image Analysis Software
    Our main user’s guide is delivered with every image analysis software order. On the installation CD-ROM you can find PDF files of every manual in various languages as well.
  • Please have a look into the attached document to find the basics of the Online Shading Correction.

    Online_Shading_Correction_DEU.pdf
    Online_Shading_Correction_ENG.pdf

  • Problems with Windows XP Service Pack 3 and non ROHS Olympus Soft Imaging Solution FireWire cameras

    Olympus Soft Imaging Solution has discovered a problem with non ROHS conform FireWire cameras and the Service Pack 3 of Windows XP.

    After installing the Service Pack 3 or running a fresh Windows XP installation including Service Pack 3 the Image Analysis Software cannot find the attached FireWire camera. Also in the device manager of Windows the camera is not listed under Imaging Devices. This problem is not related to the Image Analysis Software.

    All older Olympus Soft Imaging Solution FireWire cameras are affected. If you have a new ROHS compliant camera you do not have this problem. To identify if your camera is affected please check the last two digits of the serial number of your camera. If these digits lower as 61 the camera is affected.

    Please have a look to the attached documents to find out how to resolve this issue.

    SP3_rollback_ENG.zip
    XP_SP3_Camera_DEU.pdf
    XP_SP3_Camera_ENG.pdf


  • Please install the following Hotfix from Microsoft to resolve this issue:

    Hotfix KB976477:
    http://support.microsoft.com/kb/976477/en
    http://support.microsoft.com/kb/976477/de
  • In some cases the newer USB dongles keep on blinking because the computer is trying to do an automatic firmware update on the dongle (aladdin > sentinel)

    Please install the latest driver (or only the firmwareupdate), which already contains the firmwareupdate from the manufacturers website.

  • Missing DLL's in the waterfall procedure - IPP RUNTIME 5.4.3

    In some cases it happens with newer computers that the IPP (Intel Performance Primitives) are missing.

    Please install these missing files with the setup below:
    IPP_5_4_3_Runtime.ZIP
  • AnalySIS or SISXV ini corrupted - missing Add-Ins and camera control

    It can happen that with several installations of Olympus Stream, cellSens or Olympus analySIS in a Network using roaming profiles / network profiles the Stream, cellSens or Olympus analySIS files from the roaming Win folders can be overwritten by another installation.

    So it can happen that eg. only a desktop version starts up or that a different camera is selected for aquisition and the originally installed camera is missing.

    The only way to avoid this problem is to exclude the Olympus folders from the replication or to use unique names for the installations.

  • Creation of a new project in a XV SQL data base fails

    Please delete the file 'user.xml' while Stream / CellSens is closed from the following folder:

    C:users[username]AppDataroamingolympusosis[product]user.xml

    If this was not successful please also delete the 'user.xml' from the ProgramData folder:

    C:ProgramDataOlympusosis[product]user.xml

  • We can recommend the EXSYS EX-16450 FireWire card for PCIe eviroments
  • In order to downgrade a wring firmware version of the MT20 the OBSUpdate needs to started in the command line:
    obsupdate /force
  • Installing BX3 or DP26 with another FireWire device (e.g. OSIS camera)
    Please use the attached PDF document to do the correct installation.

Most difficulties in working with Micro-Manager arise from configuring the system and from problems/issues with specific devices. In both of these cases you are interacting mainly with device adapters. These device adapters have been written by several different authors, all behave slightly differently, and interact with specific hardware that has its own peculiarities. On these pages we will maintain as much information as possible about Micro-Manager device adapters. This will help you configure and understand your Micro-Manager system. We hope that the authors of the device adapters will maintain this information, but please feel free to update the information here with your own experiences. The information here will refer to the most recent Micro-Manager release.

Motorized Microscopes

Download
  • LeicaDMI - Leica DMI and DM microscopes
  • LeicaDMR - Leica DMR microscopes (and DMIRBE)
  • MoticMicroscope - Motic BA600 microscopes
  • NikonAZ100 - Nikon AZ100 Zoom microscope
  • NikonEclipse90i - Nikon Eclipse 90i motorized microscope
  • NikonTE2000 - Nikon TE2000 motorized microscope
  • NikonTI - Nikon Ti microscope
  • NikonTi2 - Nikon Ti2 microscope
  • Olympus - Olympus IX81 (Inverted)/BX61 (Upright)
  • OlympusIX83 - Olympus IX83 motorized microscope
  • ZeissCAN - Zeiss CAN-bus (not CAN29) compatible microscopes (Axiovert 200m, Axioplan2)
  • ZeissCAN29 - Zeiss CAN29-bus compatible microscopes (AxioObserver)
  • ZeissAxioZoom - Zeiss AxioZoom microscope (CAN29)

Cameras

  • ABSCamera - Cameras from ABS Gesellschaft für Automatisierung, Bildverarbeitung, Software GmbH Jena
  • AmScope - AmScope MU series cameras (Windows)
  • Andor - Andor cameras (CCD and EMCCD)
  • AndorSDK3 - New model Andor cameras (sCMOS)
  • Apogee - Apogee cameras
  • AxioCam - Zeiss AxioCam medium resolution and high resolution models (Windows)
  • BaslerAce - Basler Ace USB Cameras
  • BaslerCameras - All Basler cameras that are supported by pylon SDK
  • BaumerOptronic - Leica DFC camera (through BaumerOptronic FXLib)
  • BiostepEagleIce - biostep EagleIce camera
  • dc1394 - Firewire cameras that adhere to the iidc1394 specs (see also IIDC)
  • DECamera - Direct Electron Cameras
  • DemoCamera - Virtual, emulated equipment for testing
  • Dhyana - Dhyana/Tucsen cameras
  • DSLRRemoteCamera - Canon DSLR cameras (Windows)
  • FakeCamera - Virtual camera that loads images from disk (Windows, Linux)
  • FirstLightImagingCamera - First Light Imaging Cameras
  • FLICamera - Finger Lakes Instrumentation Cameras
  • GigECamera - GigE Vision- and GenICam-compliant cameras
  • GPhoto - Canon and Nikon DSLR cameras (Mac, Linux)
  • Hamamatsu - Legacy adapter for Hamamatsu cameras (via DCAM-API); now Mac only
  • HamamatsuHam - Hamamatsu cameras (via DCAM-API)
  • IDS_uEye - IDS uEye USB cameras (also Thorlabs DCUxxxx, Edmund EO-xxxxM) (Linux, Windows)
  • IIDC - Firewire (and USB) cameras compatible with the IIDC specification (see also dc1394)
  • JAI - JAI Cameras (eBUS)
  • Leica Cameras - These use the BaumerOptronic adapter
  • Lumenera - Lumenera cameras
  • MATRIX VISION devices - MATRIX VISION GmbH USB3 Vision, GigE Vision and USB2 cameras as well as various frame grabber boards
  • Micropix - Cameras from Micropix
  • Mightex_C_Cam - Mightex C-series USB cameras
  • MoticCamera - Motic cameras
  • NKRemoteCamera - Nikon Digital SLR (Windows)
  • OpenCVgrabber - Supports numerous USB cameras and frame grabbers (those using a DirectShow or WDM class driver). (Windows)
  • PCO_Camera - Supports all pco.sdk based cameras (pco.edge, pco.panda and others)
  • Photometrics - A.k.a. PVCAM
  • PICAM - Princeton Instruments cameras using the PICam interface
  • Piper - Stanford Photonics cameras
  • Pixelink - Pixelink Cameras
  • Point Grey Research - Point Grey (now FLIR) cameras through the Flycap2 interface, also see Spinnaker
  • PrincetonInstruments - Princeton Instruments cameras
  • ProgRes - Jenoptik cameras (ProgRes series)
  • PSRemoteCamera - Canon PowerShot camera (Windows)
  • PVCAM - Roper/Photometrics cameras (not for Princeton Instruments)
  • QCam - QImaging cameras
  • QSICamera - QSI cameras (Windows)
  • RaptorEPIX - Raptor Photonics cameras using EPIX cameralink board
  • ScionCam - Scion cameras
  • Sensicam - PCO/Cooke Sensicam camera
  • SigmaKoki - Sigma Koki camera
  • Spinnaker - FLIR (formally Point Grey) cameras though the Spinnaker interface
  • SpotCamera - Diagnostic Instruments Spot cameras
  • TetheredCam - Canon and Nikon DSLR cameras (Windows)
  • ThorlabsUSBCamera - Thorlabs cameras (Windows)
  • TIScam - The Imaging Source cameras (tested on USB/CCD models) and video frame grabbers
  • TSI - Thorlabs Scientific Imaging Cameras
  • TwainCamera - Cameras fully implementing Twain Imaging Standard
  • Veroptics - Veroptics cameras
  • Video4Linux - Video4Linux compatible cameras
  • XIMEACamera - XIMEA cameras (and some Olympus Soft Imaging cameras)


Stages, filter wheels, shutters

  • ArduinoNeoPixel - Adafruit NeoPixel RGB LEDs controlled through an Arduino
  • ASIFW1000 - ASI Shutter and Filter Wheel controller
  • ASIStage - ASI XY (and Z) stage and CRIF
  • ASITiger - ASI TG-1000 'Tiger' Controller (hub device, peripherals include multiple stage types, filter wheel, shutters, micro-mirrors, etc.)
  • ChuoSeiki_MD5000 - ChuoSeiki MD5000 series controller: 2-axis, single axis
  • ChuoSeiki_QT - ChuoSeiki QT series controller: 3-axis, 2-axis, single axis
  • CoolLED - LED illuminator (usable as a shutter device)
  • CONEX - See NewportCONEX
  • Conix - Conix Filter Changer, XY and Z stage
  • Corvus - Märzhäuser XY stages with Corvus driver.
  • DA-Z-Stage - For stages that can be controlled with analogue voltage. Needs a DA device
  • DAShutter - Treats a DA output as a shutter. Useful (for instance) for diode lasers
  • IntelLiDrive - IntelLiDrive stages are support through 3d party adapters
  • KDV - kdvelectronics focus drive (z-stage) for Meiji Techno
  • LeicaDMSTC - Leica DMSTC XY stage
  • LMT200-V3 - ITK Dr. Kassen LMT200-V3 HYDRA Controller and XY stage
  • Ludl - Ludl stages, shutters and filter wheels
  • LudlLow - Ludl stages, shutters and filter wheels (other)
  • Marzhauser - Märzhäuser XY stages and Z (uses TANGO controller)
  • MarzhauserLStep - Märzhäuser LStep stage controller
  • MarzhauserLStepOld - Old version (1.2) of Märzhäuser LStep stage controller
  • MCL_MicroDrive - Mad City Labs MicroDrive
  • MCL_NanoDrive - Mad City Labs NanoDrive
  • MT20 - Olympus MT20 illumination source (Lamp/shutter/filter wheel)
  • MP285 - Sutter Micro-Manipulator
  • NewportCONEX - Newport CONEX-CC servo controller
  • NewportSMC - Newport SMC100 single-axis motor controller
  • Nikon - Nikon Z-drive, TIRF shutter and IntensiLight shutter
  • NIMotionStage - National Instruments FlexMotion stage controls
  • NPointC400 - nPoint C.400 and LC.400 axis controllers
  • ObjectiveImaging - Objective Imaging OASIS controller
  • PI_GCS_2 - Physik Instrumente (PI) GCS2 adapter
  • PI_GCS - Physik Instrumente (PI) GCS adapter - Z Stage connected to PI GCS controller (E-665, E-621, E-625, E-753, ...)
  • PI - Other (older) Physik Instrumente devices. Includes the E-662 controller
  • PicardStage - Picard Industries USB Slide I/II and USB Twister
  • PIEZOCONCEPT - PIEZOCONCEPT nanopositioners
  • Piezosystem_30DV50 - Piezosystem Jena. digital one channel controller
  • Piezosystem_dDrive - Piezosystem Jena. digital 6 channel controller with display
  • Piezosystem_NV40_1 - Piezosystem Jena. one channel controller for older stages
  • Piezosystem_NV40_3 - Piezosystem Jena. 3 channel controller with USB
  • Piezosystem_NV120_1 - Piezosystem Jena. 1 channel controller with USB
  • PrecisExcite - LED illuminator (usable as a shutter device)
  • Prior - Prior stages, shutters, and filter wheels
  • PriorNano - Prior/Queensgate nanopositioning stages
  • RAMPS - RepRap RAMPS board as a stage controller
  • Scientifica - Scientifica stages
  • ScopeLED - DiCon LED-powered brightfield and fluorescence microscopy illuminators, implemented as shutters.
  • SigmaKoki - Sigma Koki stages and shutters
  • SmarActHCU-3D - HCU and CU SmarAct controllers adapter (XY and Z)
  • SouthPort_MicroZ - SouthPort MicroZ stage controller
  • Standa - Standa Microstep Driver
  • StandaStage - Standa Microstep Driver
  • Standa8SMC4 - Standa Microstep Driver (using XIMC interface)
  • SutterLambda - Sutter Shutters, filter wheels, light sources, etc..
  • SutterLambda2 - Sutter Lambda 10-3 controller, shutters, filter wheels, and VF5 tunable filter
  • SutterStage - Sutter XY Stage
  • Thorlabs - Thorlabs XY Stage (brushless DC motor), Piezo Z Stage and Integrated Filter Wheel
  • ThorlabsAPTStage - Thorlabs APT family linear stages
  • ThorlabsDCStage - Thorlabs Linear Stages using the TDC001 Controller (see also: ThorlabsAPTStage)
  • ThorlabsDCxxxx - Thorlabs LED controllers
  • ThorlabsElliptecSlider - Thorlabs Elliptec sliders ELL6, ELL9, ELL17 and ELL20.
  • ThorlabsFilterWheel - Thorlabs Filter Wheel
  • ThorlabsMFC1 - Thorlabs MFC1 Motorized Microscope Focus Controller
  • ThorlabsSC10 - Thorlabs shutter controller
  • Tofra - XY and Z stages, filter wheel, motorized filter cube slider, and LED illuminator
  • UserDefinedSerial - Shutters and state devices that can be controlled with simple serial commands
  • Vincent - Vincent Uniblitz controllers
  • WieneckeSinske - WSB PiezoDrive CAN XY stage
  • Xcite - EXFO X-Cite 120 PC Fluorescent Lamp / Shutter
  • XCite120PC_Exacte - Lumen Dynamics X-Cite 120PC and exacte adapter
  • XCiteLed - LED controller
  • XCiteXT600 - X-Cite TURBO and XT600 series
  • Zaber - Zaber linear and XY stages, filter wheels

Communication ports, TTLs, DAQs, etc.

  • Arduino - Open Source Programmable Digital/Analogue IO board
  • Arduino32bitBoards - 32bit Open Source Programmable Digital/Analogue IO boards
  • CustomArduino - Arduino-based devices matching existing device adapters
  • DTOpenLayer - DT OpenLayer Digital IO boards
  • ESIOImagingControllers - Microcontrollers for hardware triggering and synchronization
  • FreeSerialPort - Communicate directly through a serial port
  • ITC18 - controls shutters, cameras, pifocs, anything that can use either a TTL signal or a ±10 V signal
  • K8055 - Velleman Digital IO board (all platforms)
  • K8061 - Velleman Digital IO board (all platforms)
  • MCCDAQ - Measurement Computing PCI-DDA08/16
  • National Instruments - See NI100X and NIMultiAnalog
  • NicoLase An open-source diode laser combiner, fiber launch, and sequencing controller for fluorescence microscopy
  • NI100X - NI I/O boards - DAQmx interface
  • NIMultiAnalog - NI boards with multiple analog outputs
  • SerialManager - Serial Ports on Windows
  • SerialManagerUnix - Serial Ports on Mac and Linux
  • TriggerScope - TriggerScope digital and analog controller
  • TriggerScopeMM - TriggerScope v3 with Micro-Manager firmware
  • ParallelPort - TTLs on parallel port (Windows only)
  • USBManager - Micro-Manager internal USB communications driver

Light sources

  • AgilentLaserCombiner - Agilent MLC
  • AndorLaserCombiner - Andor laser launch
  • BlueboxOptics_niji - Bluebox Optics niji 7 channel LED light source
  • CoboltOfficial - Cobolt lasers 06-01 Series, Cobolt Skyra
  • Cobolt - Cobolt laser controller
  • CoherentCube - Coherent CUBE laser controller
  • CoherentOBIS - Coherent OBIS laser controller (Single Laser Remote)
  • Coherent Scientific Remote - Coherent OBIS laser controller (Scientific Remote and Single Laser Remote)
  • LaserQuantumLaser - gem/ventus/opus/axiom series from LaserQuantum
  • Lumencor Light Engine - All Lumencor Light Engine models
  • LumencorSpectra - Solid state illuminator from Lumencor
  • Mightex - LED driver/controllers
  • Mightex_BLS - BLS Control Modules
  • MightexPolygon - Mightex Polygon multiwavelength patterned illuminators
  • Omicron - Omicron Laser Controller
  • Oxxius - Oxxius Laser Controller
  • Oxxius_combiner - Oxxius combiner; hub for multiple laser sources
  • PolychromeV - Illumination system from Till Photonics
  • Prairie Aurora Laser Launch - Prairie Aurora Laser Launch Interfacing using a Velleman K8061
  • Sapphire - Lasers from Coherent
  • Skyra - Skyra laser controller
  • Stradus - Vortran Stradus laser driver
  • Toptica_iBeamSmartCW - Toptica iBeamSmart laser series
  • Toptica_iChrome_MLE - Toptica iChrome Multi Laser Engine
  • Toptica_iChrome_MLE_TCP - Toptica iChrome Multi Laser Engine over TCP link
  • USB_Viper_QPL - Excelitas/Qioptiq iFLEX-Viper Laser Engine
  • Versalase - Vortran Versalase laser driver
  • YodnLighting - YODN Lighting lamp device adapter for E600 serial products

Other devices

Olympus 1394 Driver Download Windows 10

  • AAAOTF - AOTF controller from AA Optoelectronics
  • Aladdin - Syring pump controller from Aladdin
  • AndorShamrock - Andor Shamrock Spectrographs
  • Aquinas - Aquinas Microfluidics Controller
  • AOTF - NEOS AOTF control through parallel port. Can be used for any TTL-controllable shutter
  • ASIwptr - ASI well-plate transfer robot
  • CARVII - BD/CrEST CARV II spinning disk confocal
  • Diskovery - Spectral/Andor spinning disk confocal/TIRF module
  • DLP4000 - Digital Mirror Device
  • GenericSLM - Any spatial light modulator that can be controlled via computer video output port.
  • ImageProcessorChain - Virtual device driver for processing images in C++
  • LumencorCIA - Camera synchronization for the Lumencor Spectra
  • MaestroServo - Pololu Maestro Servo controller
  • MicroPoint - Galvo-based phototargeting device from Andor
  • Mosaic3 - Andor Mosaic DMD Projection Device
  • Okolab - Okolab Microscope Incubators and Gas Controllers
  • OVP_ECS2 - Optic Valley Photonics ECS-2 environmental controller
  • Pecon - Pecon Incubation System
  • PeCon2000 - PeCon 2000 Incubation Controllers (USB-connected)
  • pgFocus - Open Software/Hardware Focus Stabilization from BIG
  • Rapp - Rapp UGA40 photobleaching/photoactivation unit
  • SimpleAutofocus - Image-based autofocus software 'device'.
  • SpectralLMM5 - Spectral laser line controller
  • SutterMPC - Multi manipulator controller
  • Utilities - Virtual devices providing extra functionality to Micro-Manager
  • VariLC - Tunable liquid crystal polarization modulators from CRi
  • VisiTech_iSIM - VisiTech iSIM
  • Yokogawa - Yokogawa CSU22
  • Yokogawa CSUW1 - Yokogawa CSUW1
  • Yokogawa CSUX - Yokogawa CSUX
  • XLight - CrestOptics X-Light spinning disc confocal system
  • The HSi-300 Hyperspectral Imager can be controlled with Micro-Manager (not yet included in the distribution, contact Gouch & Housego for details)

Olympus 1394 Driver Download Windows 7

Retrieved from 'https://micro-manager.org/w/index.php?title=Device_Support&oldid=11823'